GEO-TRACE-PAK
Pre-calibration package
Quantitatively analyze trace elements and major oxides in a wide range of minerals and geological samples
GEO-TRACE-PAK is a pre-calibration package that provides a quantitative application set including calibration, measuring conditions and analysis parameters. Since the pre-calibration package is pre-installed at our factory, analysis work can start soon after system installation is completed.
GEO-TRACE-PAK was developed from over one hundred certified reference materials (geological and ore samples) by the pressed powder method. Using this package, quantitative analysis of 26 trace elements can be carried out. The analysis results of 9 major components are used to correct for the trace element analysis. Two multi-element glass disks included in the package are used for maintenance of the calibration curves.
GEO-TRACE-PAK Overview
GEO-TRACE-PAK is applicable to Rigaku's ZSX Primus IV, ZSX Primus IVi and ZSX Primus III NEXT sequential wavelength-dispersive (WD) XRF spectrometer. An optional analyzing crystal LiF(220) is required to add better spectral resolution to the WDXRF spectrometer. In the case of ZSX Primus III NEXT, the optional Ge crystal is also required.
Contents
The contents of GEO-TRACE-PAK are as follows:
- Drift correction samples
- XRF monitor glass disks, 2 pcs.
- Validation samples
- Pressed powder disks with binder mixed, 2 pcs.(NIM-GBW07103, NIM-GBW07107)
- Binder for pressing
- SpectroBlend, 1 bottle (~200 g)
- Backup CD
- calibration curves (calibration constants)
- correction coefficients
- measurement conditions
- other application setting
- Instruction manual
The contents of the backup CD are pre-installed on the system before it is shipped. Users do not have to install the package during system installation.
Certified reference materials
A total of 101 certified reference materials (CRMs) were used to establish the GEO-TRACE-PAK calibration. The providers of the CRMs used are:
- Geological Survey of Japan
- U.S. Geological Survey
- Canada Centre for Mineral and Energy Technology
- Natural Resources of Canada
- MINTEK (South Africa)
- State Bureau of Technical Supervision, China
- National Research Council Canada
- National Institute of Standards and Technology (U.S.)
- National Research Centre of Geoanalysis (China)
- National Institute for Environmental Studies (Japan)

GEO-TRACE-PAK Features
GEO-TRACE-PAK Specifications
| Element | Concentration range (ppm) |
| Sc | 3 - 78 |
| V | 3 - 768 |
| Cr | 3 - 24000 |
| Co | 3 - 324 |
| Ni | 2 - 3780 |
| Cu | 2 - 37300 |
| Zn | 2 - 27500 |
| Ga | 1 - 37 |
| As | 4 - 1540 |
| Br | 1 - 217 |
| Rb | 1 - 800 |
| Sr | 1 - 12000 |
| Y | 1 - 718 |
| Zr | 1 - 11000 |
| Nb | 1 - 3900 |
| Mo | 1 - 15100 |
| Sn | 1 - 1723 |
| Ba | 7 - 2400 |
| La | 5 - 1340 |
| Ce | 4 - 2230 |
| Nd | 4 - 670 |
| W | 3 - 3600 |
| Pb | 2 - 41700 |
| Bi | 2 - 680 |
| Th | 2 - 1103 |
| U | 2 - 650 |
| Major components (reference) | |
| Component | Concentration range (mass%) |
| CaO | -55.1 |
| TiO₂ | -7.7 |
| Fe₂O₃ | -55.6 |
| Mn | -1.75 |
| K₂O | -15.4 |
| S | -7 |
| P₂O₅ | -2.6 |
| MgO | -49.4 |
| Na₂O | -10.7 |
GEO-TRACE-PAK Application Notes
The following application notes are relevant to this product
-
WDXRF1099 - Trace Element Analysis in Geological Samples by the Pressed Powder Method, using GEO-TRACE-PAK
GEO-TRACE-PAK Resources
Webinars
| Determining the Rare Earth Elements in Geological Minerals Accurately Using X-ray Fluorescence | Watch the Recording |
GEO-TRACE-PAK
Contact Us
Whether you're interested in getting a quote, want a demo, need technical support, or simply have a question, we're here to help.