DSC
DSC (Differential Scanning Calorimetry) measures changes in thermal energy within a sample when it is heated or cooled according to a specific temperature program. It is commonly used to examine reaction temperatures and reaction energy amounts for processes such as melting, crystallization, crystal transition, and glass transition.
Rigaku's DSC instruments feature various attachments, including industry-leading cooling units and sample observation, enhancing the devices' expandability, temperature range, and safety. This allows for multi-faceted data acquisition even for phenomena that were previously difficult to discern, making it suitable for a wider range of material analyses.
Products
DSCvesta2
DSC with industry-first self-diagnostic feature and industry's highest temperature range
Learn moreSample Observation DSCvesta2
Allows real-time observation and recording of sample changes from room temperature up to 725°C
Learn moreDSCvesta
DSC is a thermal analysis technique that quantifies the amount of energy in a reaction.
Learn moreSample Observation DSCvesta
Allows real-time observation and recording of sample changes from room temperature up to 725°C
Learn moreDSC8231
Quantifies the energy changes in reactions such as melting, transition, crystallization and glass transition temperature.
Learn moreApplication notes
Explore the example analyses to see which analytical technique is right for you.
-
TA5012 - Melting of an Extremely Small Amount of Dotriacontane
-
TA5005 - Fusion of Polyethylene
-
BATT1024 - Thermal Stability Analysis of Separators via DSC and TMA
-
B-TA1093 - DSC Evaluation of the Effect of Outdoor Exposure on the Glass Transition Temperature of Natural Rubber
-
B-TA1086 - Analysis of Polymorphic Transition of Carbamazepine -Sample Observation DSC, ChromTA (Chromatic Thermal Analysis)
-
B-TA1076 - Wax in Diesel Fuel: Crystallization (WAT) and Melting (WDT)
-
B-TA1070 - Thermal History Of Electrical Wire Insulating Sheath Polymer
-
B-TA1060 - Wax Appearance Temperature in Diesel Oil
-
B-TA1057 - Thermal behavior of water in hardened cement paste
-
B-TA1055 - Change in the glass transition temperature due to the degradation of fluoroelastomer
-
B-TA1050 - Gelatinization of Starch in Rice and Wheat Flour
-
B-TA1048 - Crystallization of LLDPE
-
B-TA1047 - Curing of Epoxy Adhesives by DSC
-
B-TA1046 - DSC measurement for crystallinity of HDPE
-
B-TA1040 - Thermal analysis of gummy candy -Part 2-~Sample observation DSC~
-
B-TA1039 - Measurement of glass transition of PMMA by dynamic DSC
-
B-TA1036 - Thermal Behavior of Paraffin Wax by Sample Observation DSC
-
B-TA1020 - Characterization of Olive Oil by DSC
-
B-TA1017 - Thermal Analysis of Pure Cocoa by DSC
-
B-TA1014 - DSC Measurement of Binary Alloys
-
B-TA1010 - Thermal Behavior of Caffeine by STA and DSC
-
B-TA1008 - Mechanochemical Effect in Caffeine
-
B-TA1007 - DSC Measurement of Friction Ballpoint Pen
Contact Us
Whether you're interested in getting a quote, want a demo, need technical support, or simply have a question, we're here to help.