NEX DE—Finished Portland Cement

Application Note EDXRF1748

EDXRF1748 banner

Scope

The analysis of finished Portland cement is demonstrated using the empirical approach.

Background

EDXRF is a simple analysis technique used in cement plants around the world. The technique is ideal for QA/QC throughout the cement production process. EDXRF can be used as a screening tool and a quality control analyzer to ensure proper composition of incoming feedstocks, raw meal mixture balances, addition of gypsum, and throughout the manufacturing process. The EDXRF analyzer also makes an excellent backup instrument for the WDXRF analyzer used for final QC and certification.

NEX DE  premium high-performance benchtop EDXRF elemental spectrometerModel: NEX DE

Calibration

Empirical calibrations were built using a set of 8 NIST SRM certified standards: 1880b, 1881a, 1884b, 1885a, 1886a, 1887b, 1888a, 1889a. Using the empirical approach, “alpha corrections” are then employed to automatically compensate for variations in X-ray absorption and enhancement effects based on each sample's elemental concentrations, thus yielding a very accurate model characterizing the cement type. It is recommended to make separate calibration methods for Raw Meal, Clinker, and Finished cements. A summary of the finished Portland cement empirical calibration is shown here.

Component Concentration range (mass%)
SiO₂ 18.637 – 22.380
Al₂O₃ 3.875 – 7.060
Fe₂O₃ 0.152 – 3.681
CaO 57.58 – 67.87
MgO 0.814 – 4.740
SO₃ 2.086 – 4.622
Na₂O 0.020 – 1.068
K₂O 0.093 – 1.228
TiO₂ 0.0840 – 0.3706
ZnO 0.0010 – 0.1070
Mn₂O₃ 0.0073 – 0.2588
SrO 0.0180 – 0.6380

Recovery and repeatability

To demonstrate repeatability (precision), NIST SRM 1887b was chosen from the set of calibration standards. The sample was measured in static position for ten repeat analyses with typical results shown below.

NIST SRM 1887b Standard value Average value Standard deviation % Relative deviation
SiO₂ 19.59 19.63 0.04 0.2%
Al₂O₃ 4.911 4.954 0.007 0.2%
Fe₂O₃ 2.471 2.445 0.004 0.2%
CaO 61.15 61.09 0.09 0.2%
MgO 3.624 3.591 0.036 1.0%
SO₃ 4.599 4.563 0.019 0.4%
Na₂O 0.288 0.272 0.026 9.6%
K₂O 0.961 0.958 0.011 1.2%
TiO₂ 0.203 0.212 0.007 3.4%
ZnO 0.0156 0.0149 0.0002 1.1%
Mn₂O₃ 0.0860 0.0890 0.0012 1.3%
SrO 0.2625 0.2616 0.0002 0.1%

Reducing the total analysis time to 600 sec results in an increase in each standard deviation by a factor of 1.4.

Conclusion

The Rigaku NEX DE combines direct excitation with special tube filters and a high- performance, high-throughput SDD detector to yield the excellent performance for oxide measurements of cement.

During the entire production and processing cycle, oxide composition of the cement material must be reliably monitored to ensure optimal process control, physical characteristics of the cement, as well as profitability. The Rigaku NEX DE analyzer is an ideal tool throughout the quality control process and as a backup to WDXRF systems, making it a versatile and valuable tool for several applications within the cement industry.

Contact Us

Whether you're interested in getting a quote, want a demo, need technical support, or simply have a question, we're here to help.