Defective Site Analysis of LED package by CT slices and Volume Rendering

Application Note B-XRI1003

Introduction

In micro X-ray CT, projection images of X-rays transmitted through a minute object are reconstructed to produce a high-resolution 3D transmission image. By displaying the reconstruction image in 2D slices and 3D volume renderings, the inner structures and defects in the object can be analyzed non-destructively. Here, a damaged LED package was subjected to X-ray micro CT and a defective site was revealed. 

Measurements and results

The damaged LED package (Figure 1) was subjected to X-ray micro CT at 1.3 μm/voxel resolution in six hours. Figure 2 shows a slice view of the reconstructed image. The slice view provides cross sections at arbitrary positions as if one is actually slicing the sample. A defective site encompassing two LED chips was found (shown by the red arrow in Figure2). Figure 3 shows a volume rendering view of the reconstructed image. By displaying the 3D volume rendering, one can understand the positional relationships among the LED chips and the bonding wires that the 2D slice view couldn’t clarify. A bonding wire was found to be disconnected. As shown here, 3D micro X-ray CT can magnify and visualize the inner structure of micro objects. It can not only elucidate the shapes and positions of inner objects but also measure distances between them. 

B-XCT1003 Figure 1 A broken LED package

Figure 1: A broken LED package 


B-XCT1003 Figure 2 A CT slice image of the LED package

Figure 2: A CT slice image of the LED package 


XCT1003 Figure 3 A CT volume rendering image of the LED package

Figure 3: A CT volume rendering image of the LED package

Contact Us

Whether you're interested in getting a quote, want a demo, need technical support, or simply have a question, we're here to help.